8
2. Press the steam trigger (7) and keep it pressed until steam stops producing.
3. Wait for the device to cool down for about 12-20 minutes, depending on the amount of steam remaining inside.
4. Slowly unscrew the safety cap (1) and wait a few seconds for the remaining steam to escape.
5. Slowly fill the tank with water or a mixture of tap water and distilled water. Make sure you do not pour more than 400 ml. (350 ml
recommended)
6. Close the safety cap (1) again.
NOTES:
The steam cleaner has an overheat protection system. It will automatically turn off if it overheats. Note that the device may break
down if used too many times with an empty tank. Make sure there is enough water in the tank at all times during operation.
Description and use of accessories:
D. Flat brush
Insert the large nozzle into the notch of the flat brush (3C) and turn it clockwise until you hear a click (3C). It can clean flat surfaces
such as windows, etc. After use, remove the flat brush by turning it counterclockwise.
For cleaning desks and chairs, bookcases or ironing clothes, place a white towel on the flat brush (3C).
E. Large nozzle
The large nozzle comes in handy when cleaning corners.
To attach, connect the wider end of the nozzle to the steam outlet so that the safety clip snaps into place. (3B)
F. Extension hose
If the surface you are trying to clean is difficult to access, use an extension hose.
To attach the wider end of the hose to the steam outlet, connect so that the safety clip snaps into place.
G, H. Nylon and stainless steel brush
Insert the large nozzle (E) into the notch of the round brush (3D) and turn it clockwise until you hear a click (3D). After use, remove
the round brush by turning it counterclockwise.
K. Extension tube x 3
If the cleaning area is difficult to access or the device is used to clean floors or glass in high places, you can use it with an
extension tube. The way it works is as follows: connect the tip of the extension tube to the steam outlet until the stationary lock is
completely clipped into the extension tube opening (as in the case of the large 3B nozzle) and locked in place with a clicking sound
means the assembly is complete. Note that using the extension tube will lower the temperature of the steam. Depending on the
temperature of the tube, the steam coming out of the nozzle may vary.
I. Floor brush
Use a floor brush to clean the floor.
Connect two or three extension tubes (K) to the unit together. Attach the other end of the extension tubes to the floor brush. On the
sides of the brush, press the buttons to open the attachment clamps, insert the floor towel (L) into the open clamps. After use,
remove the towel and dry/wash before next use.
Cleaning:
1. Before cleaning, unplug the power plug from the outlet.
2. Allow the steam cleaner to cool before storing.
3. Wipe the steam cleaner and accessories with a damp cloth. Let all parts dry completely.
Storage:
All parts must be completely dry before storage.
- Always store the steam cleaner in a dry, clean and dust-free place.
- Store the steam cleaner under lock, place it so that the device is inaccessible to children.
Troubleshooting
Problem:
No steam is coming out of the nozzle
Cause: The plug is not inserted into the power outlet
Solution: Plug the device into an outlet
Cause: No water in the tank.
Solution: Pour water into the tank.
Cause: The steam button is not pressed.
Solution: Release the child access lock and press the steam button.